Moulded Case Circuit Breaker(MCCB) (RLMC01)
![]() Moulded Case Circuit Breaker(MCCB) (RLMC01) |
Product Description
Products' brief:
High quality & breaking capacity MCCB
With current adjustable function
Maxi current up to 1600A
For distribute energy of electric and infrequent making and breaking circuit in normal condition
The circuit-breakers are provided with the function of the protection against overload and short circuit and under-voltage
The control circuit of the accessories is set apart with the main circuit, and doesn't need to open the cover of the circuit-breaker when install the accessories
Electrical
MC-125 MC-160 MC-250 MC-400 MC-630 MC-800 MC-1600
Design according to IEC60947-2
Rated Frequency AC 50/60Hz
Pole number 1, 2, 3, 4 3, 4 3
Rated insulation voltage Ui 500V 690V
Rated operating voltage AC 690V or below
Rated operating current 12.5-1600A
Ultimate short circuit breaking capacity lcu(KA)
AC 380V 25 35 35 35 35 35 50
AC 660V - 8 14 18 20 20 20
Rated SC serrice breaking capocity Ics(%icu) 50% 75% 100% 100% 100% 100% 100%
Utilization category A
Thermal magnetic release
Rated current In(A) 12.5-125 16-160 100-250 225-400 400-630 630-800 -
Note T/M fixed T adjustable(0.7~1In) M fixed T/M fixed T/M fixed -
Electronic release
Rated current In(A) - - - 320, 400 630 800 1000, 1250, 1600
I1=0.4...1 x In RLMC01 PR211(L-LI)
I1=0.4...1 x In RLMC01 PR212(LSI-LSIGI)
Tripping between 1.05...1.3 x I1
(IEC60947-2) I2t=constant (Long-time overload protection)
I2=1-2-3-4-6-8-10 x In
T2=0.05s, 0.1s, 0.25s, 0.5s adjustable
(Short-circuit short time delay protection)
I3=1.5-2-4-6-8-10-12 x In
(Instantaneous short-circuit protection)
I4=0.2-0.3-0.4-0.6-0.8-0.9-1 x In
T4=0.1s, 0.2s, 0.4s, 0.8s adjustable (Earth fault protection)
Note
Note: T-thermal M-magnetic L-long time S-short time relay I-instantaneous G-earth fault
RLMC01-125/160 In=12.5, 16, 20, 32, 40 magnetic protection that is fixed at 500A.
Mechanical
Frame size refer to following overall dimensions
Device height refer to following overall dimensions
Device width refer to following overall dimensions
Mounting Mounting on backplate of closure
Degree of protection IP20
Upper and lower terminals open mouthed/lift screw terminals
Terminal protection finger and hand touch safe
Installation Circuit breaker may be mounted vertically, horizontally or flat on their back without any derating of characteristics
Connection Front panel connection, black panel connection, plug-in connection
| Model NO.: | RLMC01 |
| Company: | Ru-Lena Ind. (Holding) Co., Ltd. |
Other products from this company
Most Popular
-

Mini Circuit Breaker CXB1-63(DZ47) CXB1-63 mini circuit breaker has advanced ... -

MCB (Mini Circuit Breaker)-C45N Series C45N series circuit breaker is used in lighting ... -

Mini Circuit Breaker Mini circuit breaker 63A-100A Specification ...
-

Residual Current Breakers (LEB30L-32) LEB30L-32 Residual Current Breakers with Overload ... -

Motor Protection Circuit Breaker DZX7, DZ108, DZS8 series Motor Protection Circuit ... -

Portable GPS + Mobile Phone Jammer (JH_JAM_007) Product Specifications: * Isolating Signal ...
-

Lightning Arrester(Hy5w-24) Lightning Arrester: Rated voltage: ... -

Solar PV Junction Box for Solar Panel Module (PV-CY801) Solar PV Junction Box for Solar Panel Module ... -

SPD - Surge Protective Device (TNR-B30/3+NPE) TNR-B30 series surge protector device is ...
-

Fuse (JH-15) We are a manufacturer of fuse in China with a ... -

Out Door AC Air Break Switch Out door ac air break switch-solated switches / ... -

Mini Circuit Breaker The design on the base of the current-limiting ...
-

Circuit Breaker (EE-30A) Voltage: 240V 50Hz Amp. 30A -

AEGN Mini Circuit Breaker The miniature circuit breakers is used for the ... -

Fuse Cutout Main material: Porcelain, hot dip galvanized ...
Quick Products |
Inquiry Basket (