MIC Chinese Simplified Chinese Traditional English

Home » Product Directory » Electrical & Electronics » Breaker & Protector » Moulded Case Circuit Breaker(MCCB) (RLMC01)

Add to Basket

Moulded Case Circuit Breaker(MCCB) (RLMC01)

Moulded Case Circuit Breaker(MCCB) (RLMC01)
Moulded Case Circuit Breaker(MCCB) (RLMC01)

Product Description

Products' brief:
High quality & breaking capacity MCCB
With current adjustable function
Maxi current up to 1600A
For distribute energy of electric and infrequent making and breaking circuit in normal condition
The circuit-breakers are provided with the function of the protection against overload and short circuit and under-voltage
The control circuit of the accessories is set apart with the main circuit, and doesn't need to open the cover of the circuit-breaker when install the accessories

Electrical
MC-125 MC-160 MC-250 MC-400 MC-630 MC-800 MC-1600
Design according to IEC60947-2
Rated Frequency AC 50/60Hz
Pole number 1, 2, 3, 4 3, 4 3
Rated insulation voltage Ui 500V 690V
Rated operating voltage AC 690V or below
Rated operating current 12.5-1600A
Ultimate short circuit breaking capacity lcu(KA)
AC 380V 25 35 35 35 35 35 50
AC 660V - 8 14 18 20 20 20
Rated SC serrice breaking capocity Ics(%icu) 50% 75% 100% 100% 100% 100% 100%
Utilization category A
Thermal magnetic release
Rated current In(A) 12.5-125 16-160 100-250 225-400 400-630 630-800 -
Note T/M fixed T adjustable(0.7~1In) M fixed T/M fixed T/M fixed -

Electronic release
Rated current In(A) - - - 320, 400 630 800 1000, 1250, 1600

I1=0.4...1 x In RLMC01 PR211(L-LI)
I1=0.4...1 x In RLMC01 PR212(LSI-LSIGI)
Tripping between 1.05...1.3 x I1
(IEC60947-2) I2t=constant (Long-time overload protection)
I2=1-2-3-4-6-8-10 x In
T2=0.05s, 0.1s, 0.25s, 0.5s adjustable
(Short-circuit short time delay protection)
I3=1.5-2-4-6-8-10-12 x In
(Instantaneous short-circuit protection)
I4=0.2-0.3-0.4-0.6-0.8-0.9-1 x In
T4=0.1s, 0.2s, 0.4s, 0.8s adjustable (Earth fault protection)

Note
Note: T-thermal M-magnetic L-long time S-short time relay I-instantaneous G-earth fault
RLMC01-125/160 In=12.5, 16, 20, 32, 40 magnetic protection that is fixed at 500A.

Mechanical
Frame size refer to following overall dimensions
Device height refer to following overall dimensions
Device width refer to following overall dimensions
Mounting Mounting on backplate of closure
Degree of protection IP20
Upper and lower terminals open mouthed/lift screw terminals
Terminal protection finger and hand touch safe
Installation Circuit breaker may be mounted vertically, horizontally or flat on their back without any derating of characteristics
Connection Front panel connection, black panel connection, plug-in connection